I've done some measurements on my KH1 (Serno 00845 FW 1.25)

Basics

Meter - SIGLENT SSA3021X

40dB PAD - Weinschel 58-40-33

 

Fully charged internal battery and ATU bypassed

7.0 MHz

KH1 7M BAT

 

10.1 MHz

KH1 10M BAT

 

14.0 MHz 

KH1 14M BAT

 

18.1 MHz

KH1 18M BAT

 

21.0 MHz 

KH1 21M BAT

 

Summary

Band Pwr 3rd Harmonic 5th Harmonic
7 MHz 5,93W -65,75dB -54,3dB
10MHz 5,72W -56,24dB -60,5dB
14MHZ 5,78W -59,57dB  
18MHz 5,93W -53,23dB  
21MHz 5,92W -60,95dB  

 